Release notes - device data for Vitogate 200, type KNX The release notes in the ETS product database are at: vitogateupdate.viessmann.com/200/knx/ets/4/en/releasenotes-en-knxprod.txt -------------------------------------------------------------------------------- Version 5.4.28 2019-09-26: -------------------------- Correction of different labels DE and EN in the device data. Data format corrected for various data points. Data point coverage and comparison with the Vitogate 300, type BN/MB, revised for all supported control units. Data points "PV output in 0.01kW (phase 1)", "PV output in 0.01kW (phase 2)" and "PV output in 0.01kW (phase 3)" corrected; these are now read-only. Version 5.4.22 2018-04-05: -------------------------- Correction of different labels DE and EN in the device data. Partial support of the energy cockpit for Vitodens 3xx-W/F with Vitotronic 200 (type HO2B) and for Vitodens 3xx-W/F with Vitotronic 200 (type HO2B, 2016) was added. From the software version SW3476 onwards, in the case of the heat pumps Vitocal xxx-G with Vitotronic 200 (type WO1C), Vitocal xxx-A with Vitotronic 200 (type WO1C) and Vitocal xxx-S with Vitotronic 200 (type WO1C) / Vitocaldens / Vitolacaldens, new data points for "Operating mode HC1", "Operating mode HC2", "Operating mode HC3", "Party mode HC1", "Party mode HC2", "Party mode HC3", "Economy mode HK1", "Economy mode HK2", "Economy mode HK3", "GueltBetriebsartWarmwasser" (valid operating mode DHW), "Operating mode ventilation", "Party mode ventilation", "Economy mode ventilation", "Once-only DHW heating" and "Operating mode, refrigerant circuit" are supported. These data points can now be read and written as specified. For the data point "Room temperature control cooling circuit", the DPT was corrected for heat pumps. Known error: If the DPT of a data point was corrected in the device data, then the data point must be completely removed from the planning of the ETS plugin. After saving and closing the ETS plugin, and opening it again, it may be added to the project once again. Known error: The data point "Ranking room temperature sensor separate cooling circuit" can be neither correctly read nor written in the case of heat pumps. Version 5.4.18 2017-09-18: -------------------------- As of this release, the following features have been implemented: 1) Support of separate cooling circuit for WO1C-based Vitocal heat pumps. 2) Additional data points for Vitovalor. 3) Support of Vitocrossal 100 (type CI1) with Vitotronic 100 (type GC7B) and Vitotronic 200 (type GW7B). Please also note the following: Correction of various DE and EN labels for the ETS plug-in and device data. Support for the refrigeration function has been expanded and the separate refrigeration circuit has been added to Vitocal xxx-G with Vitotronic 200 (model WO1C), Vitocal xxx-A with Vitotronic 200 (model WO1C) and Vitocal xxx-S with Vitotronic 200 (model WO1C)/Vitocaldens/Vitolacaldens. Individual data points have been added to the device data for different control units. Known bug: The wrong unit is used under "Send after change" in the ETS plug-in for DPT 9.007, 9.008, 9.024, 13.002 and 13.100. This is purely a display problem with the ETS plug-in. The data is read correctly on the KNX and also written correctly where supported. Known error: The scaling is not correct for DPT 13.002. The value read at KNX must be multiplied by 10,000. Values to be written must be divided by 10,000 if the affected data point permits writing. Known error: The scaling is not correct for DPT 9.007, 9.008 and 9.024. The value read at KNX must be multiplied by 10. Values to be written must be divided by 10 if the affected data point permits writing. Known bug: Since the initial release 5.4.0 it is not possible to write the data points "Operating mode HC1", "Operating mode HC2", "Operating mode HC3", "Party mode HC1", "Party mode HC2", "Party mode HC3", "Economy mode HC1", "Economy mode HC2", "Economy mode HC3", "Valid operating mode DHW", "Operating mode ventilation", "Party mode ventilation", "Economy mode ventilation" and "Once- only DHW heating" with heat pumps (if the specific data point is available in the relevant control unit). Known error: Reading and writing of the "operating mode, refrigerant circuit" data point is not possible in Vitocal xxx-G with Vitotronic 200 (model WO1C), Vitocal xxx-A with Vitotronic 200 (model WO1C) and Vitocal xxx-S with Vitotronic 200 (model WO1C)/Vitocaldens/Vitolacaldens. Known error: The "set room temperature, ventilation" data point cannot be written in Vitodens 3xx-W/F with Vitotronic 200 (type HO2B, 2016). Version 5.4.14 2017-03-01: -------------------------- Correction of various DE and EN labels for the ETS plug-in and device data. Detection of external H1 extension added. The display conditions for "Set DHW temperature" and "Solar collector temperature" have been corrected in several control units. Detection of the Vitosolic 100/200 extensions in the Vitocal 300-G with WPR 300 and the Vitocal 300-A with WPR 300 corrected. Display of "(6000) Select temperature" and "(600C) Second set value" has been corrected in the Vitocal 300-G with WPR 300 and the Vitocal 300-A with WPR 300. Version 5.4.12 2017-02-13: -------------------------- Correction of various DE and EN labels for the ETS plug-in and device data. With the Vitocal 300-G with WPR 300 and the Vitocal 300-A with WPR 300, the two data points "Operating mode, heating circuit HC2" and "Operating mode, heating circuit HC3" have been corrected. For the external H1 extension, the data point "Input 0-10 V" has been corrected. For the external EA1 extension, the data point "EA1: external set value 0-10 V" has been corrected. For the 0-10 V function extension, the data point "External set value via 0-10 V interface" has been corrected. Version 5.4.8 2016-07-21: ------------------------- Correction of various DE and EN labels for the ETS plug-in and device data. Missing data points have been added to the device data for various control units. These are documented in the following table: vitogateupdate.viessmann.com/200/knx/ets/4/de/added-datapoints-5-4-8.zip Version 5.4.6 2016-05-20: ------------------------- Additional new labels DE and EN for the ETS plug-in, due to corrections. Version 5.4.4 2016-05-17: ------------------------- The Vitocal 300-G with WPR300 was added, as this was previously missing from the device data. Corrected labels DE and EN for device data. Additional new labels DE and EN for the ETS plug-in, due to corrections. Version 5.4.2 2016-04-26: ------------------------- For the Vitocal 300-A with WPR300 the following data points were added, as these had been omitted from the device data, due to an error: + Operating mode, heating circuit HC1 + Operating mode, heating circuit HC2 + Operating mode, heating circuit HC3 + Valid operating mode HC1 + Valid operating mode HC2 + Valid operating mode HC3 Corrected labels DE and EN for device data for the Vitocal 300-A with WPR300. Additional new labels DE and EN for the ETS plug-in, due to corrections. Version 5.4.0 2016-04-19: ------------------------- Initial release.